Catalyst 9500X Series Switches
CVEs (2)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-20316 | Med | 0.34 | 5.3 | 0.00 | Sep 24, 2025 | A vulnerability in the access control list (ACL) programming of Cisco IOS XE Software for Cisco Catalyst 9500X and 9600X Series Switches could allow an unauthenticated, remote attacker to bypass a configured ACL on an affected device. This vulnerability is due to the flooding of traffic from an unlearned MAC address on a switch virtual interface (SVI) that has an egress ACL applied. An attacker could exploit this vulnerability by causing the VLAN to flush its MAC address table. This condition can also occur if the MAC address table is full. A successful exploit could allow the attacker to bypass an egress ACL on an affected device. | ||
| CVE-2025-20181 | 0.00 | — | 0.00 | May 7, 2025 | A vulnerability in Cisco IOS Software for Cisco Catalyst 2960X, 2960XR, 2960CX, and 3560CX Series Switches could allow an authenticated, local attacker with privilege level 15 or an unauthenticated attacker with physical access to the device to execute persistent code at boot time and break the chain of trust. This vulnerability is due to missing signature verification for specific files that may be loaded during the device boot process. An attacker could exploit this vulnerability by placing a crafted file into a specific location on an affected device. A successful exploit could allow the attacker to execute arbitrary code at boot time. Because this allows the attacker to bypass a major security feature of the device, Cisco has raised the Security Impact Rating (SIR) of this advisory from Medium to High. |
- risk 0.34cvss 5.3epss 0.00
A vulnerability in the access control list (ACL) programming of Cisco IOS XE Software for Cisco Catalyst 9500X and 9600X Series Switches could allow an unauthenticated, remote attacker to bypass a configured ACL on an affected device. This vulnerability is due to the flooding of traffic from an unlearned MAC address on a switch virtual interface (SVI) that has an egress ACL applied. An attacker could exploit this vulnerability by causing the VLAN to flush its MAC address table. This condition can also occur if the MAC address table is full. A successful exploit could allow the attacker to bypass an egress ACL on an affected device.
- CVE-2025-20181May 7, 2025risk 0.00cvss —epss 0.00
A vulnerability in Cisco IOS Software for Cisco Catalyst 2960X, 2960XR, 2960CX, and 3560CX Series Switches could allow an authenticated, local attacker with privilege level 15 or an unauthenticated attacker with physical access to the device to execute persistent code at boot time and break the chain of trust. This vulnerability is due to missing signature verification for specific files that may be loaded during the device boot process. An attacker could exploit this vulnerability by placing a crafted file into a specific location on an affected device. A successful exploit could allow the attacker to execute arbitrary code at boot time. Because this allows the attacker to bypass a major security feature of the device, Cisco has raised the Security Impact Rating (SIR) of this advisory from Medium to High.