Sma7210 Firmware
by SonicWall
CVEs (12)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-23006 | Cri | 0.84 | 9.8 | 0.23 | KEV | Jan 23, 2025 | Pre-authentication deserialization of untrusted data vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) and Central Management Console (CMC), which in specific conditions could potentially enable a remote unauthenticated attacker to execute… | |
| CVE-2024-6387 | Hig | 0.64 | 8.1 | 1.00 | Jul 1, 2024 | A security regression (CVE-2006-5051) was discovered in OpenSSH's server (sshd). There is a race condition which can lead sshd to handle some signals in an unsafe manner. An unauthenticated, remote attacker may be able to trigger it by failing to authenticate within a set time… | ||
| CVE-2022-22282 | Cri | 0.64 | 9.8 | 0.08 | May 13, 2022 | SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions incorrectly restricts access to a resource using HTTP connections from an unauthorized actor leading to Improper Access Control vulnerability. | ||
| CVE-2025-40602 | Med | 0.55 | 6.6 | 0.02 | KEV | Dec 18, 2025 | A local privilege escalation vulnerability due to insufficient authorization in the SonicWall SMA1000 appliance management console (AMC). | |
| CVE-2022-1701 | Hig | 0.49 | 7.5 | 0.05 | May 13, 2022 | SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions uses a shared and hard-coded encryption key to store data. | ||
| CVE-2026-4116 | Hig | 0.47 | 7.2 | 0.00 | Apr 9, 2026 | Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN user to bypass Workplace/Connect Tunnel TOTP authentication. | ||
| CVE-2026-4113 | Hig | 0.47 | 7.2 | 0.00 | Apr 9, 2026 | An observable response discrepancy vulnerability in the SonicWall SMA1000 series appliances allows a remote attacker to enumerate SSL VPN user credentials. | ||
| CVE-2026-4112 | Hig | 0.47 | 7.2 | 0.01 | Apr 9, 2026 | Improper neutralization of special elements used in an SQL command (“SQL Injection”) in SonicWall SMA1000 series appliances allows a remote authenticated attacker with read-only administrator privileges to escalate privileges to primary administrator. | ||
| CVE-2026-4114 | Med | 0.43 | 6.6 | 0.01 | Apr 9, 2026 | Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN admin to bypass AMC TOTP authentication. | ||
| CVE-2022-1702 | Med | 0.40 | 6.1 | 0.09 | May 13, 2022 | SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions accept a user-controlled input that specifies a link to an external site and uses that link in a redirect which leads to Open redirection vulnerability. | ||
| CVE-2026-15410 | Hig | 0.24 | 7.2 | 0.76 | KEV | Jul 14, 2026 | Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute… | |
| CVE-2026-15409 | Cri | 0.24 | 10.0 | 0.74 | KEV | Jul 14, 2026 | A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. A remote unauthenticated attacker could potentially cause the appliance to make requests to unintended location. |
- risk 0.84cvss 9.8epss 0.23
Pre-authentication deserialization of untrusted data vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) and Central Management Console (CMC), which in specific conditions could potentially enable a remote unauthenticated attacker to execute…
- risk 0.64cvss 8.1epss 1.00
A security regression (CVE-2006-5051) was discovered in OpenSSH's server (sshd). There is a race condition which can lead sshd to handle some signals in an unsafe manner. An unauthenticated, remote attacker may be able to trigger it by failing to authenticate within a set time…
- risk 0.64cvss 9.8epss 0.08
SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions incorrectly restricts access to a resource using HTTP connections from an unauthorized actor leading to Improper Access Control vulnerability.
- risk 0.55cvss 6.6epss 0.02
A local privilege escalation vulnerability due to insufficient authorization in the SonicWall SMA1000 appliance management console (AMC).
- risk 0.49cvss 7.5epss 0.05
SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions uses a shared and hard-coded encryption key to store data.
- risk 0.47cvss 7.2epss 0.00
Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN user to bypass Workplace/Connect Tunnel TOTP authentication.
- risk 0.47cvss 7.2epss 0.00
An observable response discrepancy vulnerability in the SonicWall SMA1000 series appliances allows a remote attacker to enumerate SSL VPN user credentials.
- risk 0.47cvss 7.2epss 0.01
Improper neutralization of special elements used in an SQL command (“SQL Injection”) in SonicWall SMA1000 series appliances allows a remote authenticated attacker with read-only administrator privileges to escalate privileges to primary administrator.
- risk 0.43cvss 6.6epss 0.01
Improper handling of Unicode encoding in SonicWall SMA1000 series appliances allows a remote authenticated SSLVPN admin to bypass AMC TOTP authentication.
- risk 0.40cvss 6.1epss 0.09
SonicWall SMA1000 series firmware 12.4.0, 12.4.1-02965 and earlier versions accept a user-controlled input that specifies a link to an external site and uses that link in a redirect which leads to Open redirection vulnerability.
- risk 0.24cvss 7.2epss 0.76
Post-authentication improper control of generation of code ('Code Injection') vulnerability has been identified in the SMA1000 Appliance Management Console (AMC) which in specific conditions could potentially enable a remote authenticated attacker as administrator to execute…
- risk 0.24cvss 10.0epss 0.74
A Server-side request forgery (SSRF) vulnerability has been identified in the SMA1000 Appliance Work Place interface. A remote unauthenticated attacker could potentially cause the appliance to make requests to unintended location.