| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2018-13805 | Hig | 0.49 | 7.5 | 0.02 | Oct 10, 2018 | A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a… | ||
| CVE-2017-12741 | Hig | 0.49 | 7.5 | 0.03 | Dec 26, 2017 | Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. | ||
| CVE-2018-3639 | Med | 0.44 | 5.5 | 0.61 | May 22, 2018 | Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis,… | ||
| CVE-2017-2681 | Med | 0.42 | 6.5 | 0.01 | May 11, 2017 | Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. | ||
| CVE-2017-2680 | Med | 0.42 | 6.5 | 0.01 | May 11, 2017 | Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected. |
- risk 0.49cvss 7.5epss 0.02
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a…
- risk 0.49cvss 7.5epss 0.03
Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually.
- risk 0.44cvss 5.5epss 0.61
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis,…
- risk 0.42cvss 6.5epss 0.01
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
- risk 0.42cvss 6.5epss 0.01
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.