VYPR

Scalance X408 Firmware

by Siemens Foundation

CVEs (5)

  • CVE-2018-4833HigJun 14, 2018
    risk 0.57cvss 8.8epss 0.01

    A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1),…

  • CVE-2017-2681MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.

  • CVE-2017-2680MedMay 11, 2017
    risk 0.42cvss 6.5epss 0.01

    Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.

  • CVE-2014-8479Jan 21, 2015
    risk 0.00cvss epss 0.01

    The FTP server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote authenticated users to cause a denial of service (reboot) via crafted FTP packets.

  • CVE-2014-8478Jan 21, 2015
    risk 0.00cvss epss 0.02

    The web server on Siemens SCALANCE X-300 switches with firmware before 4.0 and SCALANCE X 408 switches with firmware before 4.0 allows remote attackers to cause a denial of service (reboot) via malformed HTTP requests.