| CVE-2017-2349 | Cri | 0.65 | 9.9 | 0.03 | | Jul 17, 2017 | A command injection vulnerability in the IDP feature of Juniper Networks Junos OS on SRX series devices potentially allows a user with login access to the device to execute shell commands and elevate privileges. Affected releases are Juniper Networks Junos OS 12.1X44 prior to 12.1X44-D60; 12.1X46 prior to 12.1X46-D50; 12.1X47 prior to 12.1X47-D30, 12.1X47-D35; 12.3X48 prior to 12.3X48-D20, 12.3X48-D30; 15.1X49 prior to 15.1X49-D20, 15.1X49-D30. |
| CVE-2017-2343 | Cri | 0.65 | 10.0 | 0.03 | | Jul 17, 2017 | The Integrated User Firewall (UserFW) feature was introduced in Junos OS version 12.1X47-D10 on the Juniper SRX Series devices to provide simple integration of user profiles on top of the existing firewall polices. As part of an internal security review of the UserFW services authentication API, hardcoded credentials were identified and removed which can impact both the SRX Series device, and potentially LDAP and Active Directory integrated points. An attacker may be able to completely compromise SRX Series devices, as well as Active Directory servers and services. When Active Directory is compromised, it may allow access to user credentials, workstations, servers performing other functions such as email, database, etc. Inter-Forest Active Directory deployments may also be at risk as the attacker may gain full administrative control over one or more Active Directories depending on the credentials supplied by the administrator of the AD domains and SRX devices performing integrated authentication of users, groups and devices. To identify if your device is potentially vulnerable to exploitation, check to see if the service is operating; from CLI review the following output: root@SRX-Firewall# run show services user-identification active-directory-access domain-controller status extensive A result of "Status: Connected" will indicate that the service is active on the device. To evaluate if user authentication is occurring through the device: root@SRX-Firewall# run show services user-identification active-directory-access active-directory-authentication-table all Next review the results to see if valid users and groups are returned. e.g. Domain: juniperlab.com Total entries: 3 Source IP Username groups state 172.16.26.1 administrator Valid 192.168.26.2 engg01 engineers Valid 192.168.26.3 guest01 guests Valid Domain: NULL Total entries: 8 Source IP Username groups state 192.168.26.4 Invalid 192.168.26.5 Invalid This will also indicate that Valid users and groups are authenticating through the device. Affected releases are Juniper Networks Junos OS 12.3X48 from 12.3X48-D30 and prior to 12.3X48-D35 on SRX series; 15.1X49 from 15.1X49-D40 and prior to 15.1X49-D50 on SRX series. Devices on any version of Junos OS 12.1X46, or 12.1X47 are unaffected by this issue. |
| CVE-2017-10615 | Cri | 0.64 | 9.8 | 0.02 | | Oct 13, 2017 | A vulnerability in the pluggable authentication module (PAM) of Juniper Networks Junos OS may allow an unauthenticated network based attacker to potentially execute arbitrary code or crash daemons such as telnetd or sshd that make use of PAM. Affected Juniper Networks Junos OS releases are: 14.1 from 14.1R5 prior to 14.1R8-S4, 14.1R9; 14.1X53 prior to 14.1X53-D50 on EX and QFX series; 14.2 from 14.2R3 prior to 14.2R7-S8, 14.2R8; No other Junos OS releases are affected by this issue. No other Juniper Networks products are affected by this issue. |
| CVE-2017-2345 | Cri | 0.64 | 9.8 | 0.03 | | Jul 17, 2017 | On Junos OS devices with SNMP enabled, a network based attacker with unfiltered access to the RE can cause the Junos OS snmpd daemon to crash and restart by sending a crafted SNMP packet. Repeated crashes of the snmpd daemon can result in a partial denial of service condition. Additionally, it may be possible to craft a malicious SNMP packet in a way that can result in remote code execution. SNMP is disabled in Junos OS by default. Junos OS devices with SNMP disabled are not affected by this issue. No other Juniper Networks products or platforms are affected by this issue. NOTE: This is a different issue than Cisco CVE-2017-6736, CVE-2017-6737, and CVE-2017-6738. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D44, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100, 15.1X49-D110; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2, 16.2R3; 17.1 prior to 17.1R1-S3, 17.1R2, 17.1R3; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. Junos releases prior to 10.2 are not affected. |
| CVE-2017-10601 | Cri | 0.64 | 9.8 | 0.00 | | Jul 17, 2017 | A specific device configuration can result in a commit failure condition. When this occurs, a user is logged in without being prompted for a password while trying to login through console, ssh, ftp, telnet or su, etc., This issue relies upon a device configuration precondition to occur. Typically, device configurations are the result of a trusted administrative change to the system's running configuration. The following error messages may be seen when this failure occurs: mgd: error: commit failed: (statements constraint check failed) Warning: Commit failed, activating partial configuration. Warning: Edit the router configuration to fix these errors. If the administrative changes are not made that result in such a failure, then this issue is not seen. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.3 prior to 12.3R10, 12.3R11; 12.3X48 prior to 12.3X48-D20; 13.2 prior to 13.2R8; 13.3 prior to 13.3R7; 14.1 prior to 14.1R4-S12, 14.1R5, 14.1R6; 14.1X53 prior to 14.1X53-D30; 14.2 prior to 14.2R4; 15.1 prior to 15.1F2, 15.1F3, 15.1R2. |
| CVE-2016-1286 | Hig | 0.60 | 8.6 | 0.54 | | Mar 9, 2016 | named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 allows remote attackers to cause a denial of service (assertion failure and daemon exit) via a crafted signature record for a DNAME record, related to db.c and resolver.c. |
| CVE-2013-6014 | Cri | 0.60 | 9.3 | 0.00 | | Oct 28, 2013 | Juniper Junos 10.4 before 10.4S15, 11.4 before 11.4R9, 11.4X27 before 11.4X27.44, 12.1 before 12.1R7, 12.1X44 before 12.1X44-D20, 12.1X45 before 12.1X45-D15, 12.2 before 12.2R6, 12.3 before 12.3R3, 13.1 before 13.1R3, and 13.2 before 13.2R1, when Proxy ARP is enabled on an unnumbered interface, allows remote attackers to perform ARP poisoning attacks and possibly obtain sensitive information via a crafted ARP message. |
| CVE-2026-33785 | Hig | 0.57 | 8.8 | 0.00 | | Apr 9, 2026 | A Missing Authorization vulnerability in the CLI of Juniper Networks Junos OS on MX Series allows a local, authenticated user with low privileges to execute specific commands which will lead to a complete compromise of managed devices.
Any user logged in, without requiring specific privileges, can issue 'request csds' CLI operational commands. These commands are only meant to be executed by high privileged or users designated for Juniper Device Manager (JDM) / Connected Security Distributed Services (CSDS) operations as they will impact all aspects of the devices managed via the respective MX.
This issue affects Junos OS on MX Series:
* 24.4 releases before 24.4R2-S3,
* 25.2 releases before 25.2R2.
This issue does not affect Junos OS releases before 24.4. |
| CVE-2017-2341 | Hig | 0.57 | 8.8 | 0.00 | | Jul 17, 2017 | An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue. |
| CVE-2017-10605 | Hig | 0.56 | 8.6 | 0.01 | | Jul 17, 2017 | On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series. |
| CVE-2016-4924 | Hig | 0.55 | 8.4 | 0.00 | | Oct 13, 2017 | An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8 |
| CVE-2016-4922 | Hig | 0.55 | 8.4 | 0.00 | | Oct 13, 2017 | Certain combinations of Junos OS CLI commands and arguments have been found to be exploitable in a way that can allow unauthorized access to the operating system. This may allow any user with permissions to run these CLI commands the ability to achieve elevated privileges and gain complete control of the device. Affected releases are Juniper Networks Junos OS 11.4 prior to 11.4R13-S3; 12.1X46 prior to 12.1X46-D60; 12.1X47 prior to 12.1X47-D45; 12.3 prior to 12.3R12; 12.3X48 prior to 12.3X48-D35; 13.2 prior to 13.2R9; 13.3 prior to 13.3R4-S11, 13.3R9; 14.1 prior to 14.1R4-S12, 14.1R7; 14.1X53 prior to 14.1X53-D28, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R3-S10, 14.2R4-S7, 14.2R5; 15.1 prior to 15.1F4, 15.1R3; 15.1X49 prior to 15.1X49-D60; 15.1X53 prior to 15.1X53-D57, 15.1X53-D70. |
| CVE-2017-2342 | Hig | 0.53 | 8.1 | 0.00 | | Jul 17, 2017 | MACsec feature on Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series does not report errors when a secure link can not be established. It falls back to an unencrypted link. This can happen when MACsec is configured on ports that are not capable of MACsec or when a secure link can not be established. This can mislead customers into believing that a link is secure. On SRX 300 series devices, prior to 15.1X49-D100, MACsec was only supported on control and fabric ports of SRX340 and SRX345 devices. SRX300 and and SRX320 did not have any MACsec capable ports. Configuring MACsec on ports that were not MACsec capable would have resulted in this issue. Affected releases are Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series. |
| CVE-2016-4923 | Hig | 0.52 | 8.0 | 0.00 | | Oct 13, 2017 | Insufficient cross site scripting protection in J-Web component in Juniper Networks Junos OS may potentially allow a remote unauthenticated user to inject web script or HTML and steal sensitive data and credentials from a J-Web session and to perform administrative actions on the Junos device. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. Affected releases are Juniper Networks Junos OS 11.4 prior to 11.4R13-S3; 12.1X44 prior to 12.1X44-D60; 12.1X46 prior to 12.1X46-D40; 12.1X47 prior to 12.1X47-D30; 12.3 prior to 12.3R11; 12.3X48 prior to 12.3X48-D20; 13.2X51 prior to 13.2X51-D39, 13.2X51-D40; 13.3 prior to 13.3R9; 14.1 prior to 14.1R6; 14.2 prior to 14.2R6; 15.1 prior to 15.1R3; 15.1X49 prior to 15.1X49-D20; 15.1X53 prior to 15.1X53-D57. |
| CVE-2026-33793 | Hig | 0.51 | 7.8 | 0.00 | | Apr 9, 2026 | An Execution with Unnecessary Privileges vulnerability in the User Interface (UI) of Juniper Networks Junos OS and Junos OS Evolved allows a local, low-privileged attacker to gain root privileges, thus compromising the system.
When a configuration that allows unsigned Python op scripts is present on the device, a non-root user is able to execute malicious op scripts as a root-equivalent user, leading to privilege escalation.
This issue affects Junos OS:
* All versions before 22.4R3-S7,
* from 23.2 before 23.2R2-S4,
* from 23.4 before 23.4R2-S6,
* from 24.2 before 24.2R1-S2, 24.2R2,
* from 24.4 before 24.4R1-S2, 24.4R2;
Junos OS Evolved:
* All versions before 22.4R3-S7-EVO,
* from 23.2 before 23.2R2-S4-EVO,
* from 23.4 before 23.4R2-S6-EVO,
* from 24.2 before 24.2R2-EVO,
* from 24.4 before 24.4R1-S1-EVO, 24.4R2-EVO. |
| CVE-2017-2344 | Hig | 0.51 | 7.8 | 0.00 | | Jul 17, 2017 | A routine within an internal Junos OS sockets library is vulnerable to a buffer overflow. Malicious exploitation of this issue may lead to a denial of service (kernel panic) or be leveraged as a privilege escalation through local code execution. The routines are only accessible via programs running on the device itself, and veriexec restricts arbitrary programs from running on Junos OS. There are no known exploit vectors utilizing signed binaries shipped with Junos OS itself. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67; 12.3X48 prior to 12.3X48-D51, 12.3X48-D55; 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R2-S10, 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D122, 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R4-S9, 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F2-S18, 15.1F6-S7, 15.1R4-S8, 15.1R5-S5, 15.1R6-S1, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D231, 15.1X53-D47, 15.1X53-D48, 15.1X53-D57, 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R4-S4, 16.1R5; 16.2 prior to 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S1, 17.2R2; 17.2X75 prior to 17.2X75-D30. No other Juniper Networks products or platforms are affected by this issue. |
| CVE-2016-1271 | Hig | 0.51 | 7.8 | 0.00 | | Apr 15, 2016 | Juniper Junos OS before 12.1X46-D45, 12.1X47 before 12.1X47-D30, 12.3 before 12.3R11, 12.3X48 before 12.3X48-D25, 13.2 before 13.2R8, 13.3 before 13.3R7, 14.1 before 14.1R6, 14.2 before 14.2R4, 15.1 before 15.1R1 or 15.1F2, and 15.1X49 before 15.1X49-D15 allow local users to gain privileges via crafted combinations of CLI commands and arguments, a different vulnerability than CVE-2015-3003, CVE-2014-3816, and CVE-2014-0615. |
| CVE-2016-1285 | Med | 0.50 | 6.8 | 0.69 | | Mar 9, 2016 | named in ISC BIND 9.x before 9.9.8-P4 and 9.10.x before 9.10.3-P4 does not properly handle DNAME records when parsing fetch reply messages, which allows remote attackers to cause a denial of service (assertion failure and daemon exit) via a malformed packet to the rndc (aka control channel) interface, related to alist.c and sexpr.c. |
| CVE-2026-33790 | Hig | 0.49 | 7.5 | 0.00 | | Apr 9, 2026 | An Improper Check for Unusual or Exceptional Conditions vulnerability in the flow daemon (flowd) of Juniper Networks Junos OS on SRX Series allows an attacker sending a specific, malformed ICMPv6 packet to cause the srxpfe process to crash and restart. Continued receipt and processing of these packets will repeatedly crash the srxpfe process and sustain the Denial of Service (DoS) condition.
During NAT64 translation, receipt of a specific, malformed ICMPv6 packet destined to the device will cause the srxpfe process to crash and restart.
This issue cannot be triggered using IPv4 nor other IPv6 traffic.
This issue affects Junos OS on SRX Series:
* all versions before 21.2R3-S10,
* all versions of 21.3,
* from 21.4 before 21.4R3-S12,
* all versions of 22.1,
* from 22.2 before 22.2R3-S8,
* all versions of 22.4,
* from 22.4 before 22.4R3-S9,
* from 23.2 before 23.2R2-S6,
* from 23.4 before 23.4R2-S7,
* from 24.2 before 24.2R2-S3,
* from 24.4 before 24.4R2-S3,
* from 25.2 before 25.2R1-S2, 25.2R2. |
| CVE-2026-33778 | Hig | 0.49 | 7.5 | 0.00 | | Apr 9, 2026 | An Improper Validation of Syntactic Correctness of Input vulnerability in the IPsec library used by kmd and iked of Juniper Networks Junos OS on SRX Series and MX Series allows an unauthenticated, network-based attacker to cause a complete Denial-of-Service (DoS).
If an affected device receives a specifically malformed first ISAKMP packet from the initiator, the kmd/iked process will crash and restart, which momentarily prevents new security associations (SAs) for from being established. Repeated exploitation of this vulnerability causes a complete inability to establish new VPN connections.
This issue affects Junos OS on
SRX Series and MX Series:
* all versions before 22.4R3-S9,
* 23.2 version before 23.2R2-S6,
* 23.4 version before 23.4R2-S7,
* 24.2 versions before 24.2R2-S4,
* 24.4 versions before 24.4R2-S3,
* 25.2 versions before 25.2R1-S2, 25.2R2. |