Micrologix

by Rockwellautomation

CVEs (11)

  • CVE-2012-6437CriJan 24, 2013
    risk 0.64cvss 9.8epss 0.08

    The device does not properly authenticate users and the potential exists for a remote user to upload a new firmware image to the Ethernet card, whether it is a corrupt or legitimate firmware image. Successful exploitation of this vulnerability could cause loss of availability,…

  • CVE-2012-6435HigJan 24, 2013
    risk 0.52cvss 7.5epss 0.34

    When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the CPU to stop logic execution and enter a fault state, a DoS can occur. This situation could cause…

  • CVE-2012-6438HigJan 24, 2013
    risk 0.51cvss 7.5epss 0.27

    The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the NIC to crash. Successful exploitation of this…

  • CVE-2012-6436HigJan 24, 2013
    risk 0.51cvss 7.5epss 0.27

    The device does not properly validate the data being sent to the buffer. An attacker can send a malformed CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP, which creates a buffer overflow and causes the CPU to crash. Successful exploitation of this…

  • CVE-2022-3166HigDec 16, 2022
    risk 0.49cvss 7.5epss 0.01

    Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by…

  • CVE-2022-46670HigDec 16, 2022
    risk 0.46cvss 7.1epss 0.01

    Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution.  The…

  • CVE-2022-2179MedJul 20, 2022
    risk 0.42cvss 6.5epss 0.01

    The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.

  • CVE-2012-6440MedJan 24, 2013
    risk 0.32cvss 4.8epss 0.09

    The Web server password authentication mechanism used by the products is vulnerable to a MitM and Replay attack. Successful exploitation of this vulnerability will allow unauthorized access of the product’s Web server to view and alter product configuration and diagnostics…

  • CVE-2012-6441Jan 24, 2013
    risk 0.04cvss epss 0.47

    An information exposure of confidential information results when the device receives a specially crafted CIP packet to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP. Successful exploitation of this vulnerability could cause loss of confidentiality. …

  • CVE-2012-6439Jan 24, 2013
    risk 0.02cvss epss 0.23

    When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that changes the product’s configuration and network parameters, a DoS condition can occur. This situation…

  • CVE-2012-4690Dec 8, 2012
    risk 0.00cvss epss 0.04

    Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status…