Integrated Lights Out 5 Firmware
by Microfocus
CVEs (9)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2018-7093 | Hig | 0.56 | 8.6 | 0.03 | Aug 14, 2018 | A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service. | ||
| CVE-2019-11982 | Hig | 0.54 | 8.3 | 0.02 | Jun 5, 2019 | A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39. | ||
| CVE-2018-7101 | Hig | 0.49 | 7.5 | 0.07 | Sep 27, 2018 | A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30. | ||
| CVE-2018-7105 | Hig | 0.47 | 7.2 | 0.04 | Sep 27, 2018 | A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to… | ||
| CVE-2018-7078 | Hig | 0.47 | 7.2 | 0.07 | Aug 6, 2018 | A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30. | ||
| CVE-2019-11983 | Hig | 0.46 | 7.0 | 0.01 | Jun 5, 2019 | A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39. | ||
| CVE-2018-7113 | Med | 0.43 | 6.6 | 0.01 | Dec 3, 2018 | A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates. | ||
| CVE-2021-46846 | Med | 0.42 | 6.4 | 0.00 | Dec 12, 2022 | Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5. | ||
| CVE-2018-7117 | Med | 0.40 | 6.1 | 0.01 | Apr 9, 2019 | A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40. |
- risk 0.56cvss 8.6epss 0.03
A security vulnerability in HPE Integrated Lights-Out 3 prior to v1.90, iLO 4 prior to v2.60, iLO 5 prior to v1.30, Moonshot Chassis Manager firmware prior to v1.58, and Moonshot Component Pack prior to v2.55 could be remotely exploited to create a denial of service.
- risk 0.54cvss 8.3epss 0.02
A remote cross site scripting vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
- risk 0.49cvss 7.5epss 0.07
A potential remote denial of service security vulnerability has been identified in HPE Integrated Lights Out 4 prior to v2.60 and iLO 5 for Gen 10 servers prior to v1.30.
- risk 0.47cvss 7.2epss 0.04
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) for HPE Gen10 Servers prior to v1.35, HPE Integrated Lights-Out 4 (iLO 4) prior to v2.61, HPE Integrated Lights-Out 3 (iLO 3) prior to v1.90 could be remotely exploited to execute arbitrary code leading to…
- risk 0.47cvss 7.2epss 0.07
A remote code execution was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than version v2.60 and HPE Integrated Lights-Out 5 (iLO 5) earlier than version v1.30.
- risk 0.46cvss 7.0epss 0.01
A remote buffer overflow vulnerability was identified in HPE Integrated Lights-Out 4 (iLO 4) earlier than v2.61b for Gen9 servers and Integrated Lights-Out 5 (iLO 5) for Gen10 Servers earlier than version v1.39.
- risk 0.43cvss 6.6epss 0.01
A security vulnerability in HPE Integrated Lights-Out 5 (iLO 5) prior to v1.37 could be locally exploited to bypass the security restrictions for firmware updates.
- risk 0.42cvss 6.4epss 0.00
Cross Site Scripting vulnerability in Hewlett Packard Enterprise Integrated Lights-Out 5.
- risk 0.40cvss 6.1epss 0.01
A remote Cross-Site Scripting in HPE iLO 5 Web User Interface vulnerability was identified in HPE Integrated Lights-Out 5 (iLO 5) for Gen10 ProLiant Servers earlier than version v1.40.