Infotainment ECU
by Bosch
CVEs (6)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2025-32058 | Cri | 0.60 | 9.3 | 0.00 | Feb 15, 2026 | The Infotainment ECU manufactured by Bosch uses a RH850 module for CAN communication. RH850 is connected to infotainment over the INC interface through a custom protocol. There is a vulnerability during processing requests of this protocol on the V850 side which allows an… | ||
| CVE-2025-32062 | Hig | 0.57 | 8.8 | 0.00 | Feb 15, 2026 | The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a… | ||
| CVE-2025-32061 | Hig | 0.57 | 8.8 | 0.00 | Feb 15, 2026 | The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a… | ||
| CVE-2025-32059 | Hig | 0.57 | 8.8 | 0.00 | Feb 15, 2026 | The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a… | ||
| CVE-2025-32063 | Med | 0.44 | 6.8 | 0.00 | Feb 15, 2026 | There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the… | ||
| CVE-2025-32057 | Med | 0.42 | 6.5 | 0.00 | Jan 22, 2026 | The Infotainment ECU manufactured by Bosch which is installed in Nissan Leaf ZE1 – 2020 uses a Redbend service for over-the-air provisioning and updates. HTTPS is used for communication with the back-end server. Due to usage of the default configuration for the underlying SSL… |
- risk 0.60cvss 9.3epss 0.00
The Infotainment ECU manufactured by Bosch uses a RH850 module for CAN communication. RH850 is connected to infotainment over the INC interface through a custom protocol. There is a vulnerability during processing requests of this protocol on the V850 side which allows an…
- risk 0.57cvss 8.8epss 0.00
The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a…
- risk 0.57cvss 8.8epss 0.00
The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a…
- risk 0.57cvss 8.8epss 0.00
The specific flaw exists within the Bluetooth stack developed by Alps Alpine of the Infotainment ECU manufactured by Bosch. The issue results from the lack of proper boundary validation of user-supplied data, which can result in a stack-based buffer overflow when receiving a…
- risk 0.44cvss 6.8epss 0.00
There is a misconfiguration vulnerability inside the Infotainment ECU manufactured by BOSCH. The vulnerability happens during the startup phase of a specific systemd service, and as a result, the following developer features will be activated: the disabled firewall and the…
- risk 0.42cvss 6.5epss 0.00
The Infotainment ECU manufactured by Bosch which is installed in Nissan Leaf ZE1 – 2020 uses a Redbend service for over-the-air provisioning and updates. HTTPS is used for communication with the back-end server. Due to usage of the default configuration for the underlying SSL…