CVEs (8)

  • CVE-2020-12029CriJul 20, 2020
    risk 0.65cvss 9.0epss 0.45

    All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation…

  • CVE-2024-4609CriMay 16, 2024
    risk 0.64cvss 9.8epss 0.01

    A vulnerability exists in the Rockwell Automation FactoryTalk® View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack…

  • CVE-2020-12028HigJul 20, 2020
    risk 0.55cvss 7.3epss 0.51

    In all versions of FactoryTalk View SEA remote, an authenticated attacker may be able to utilize certain handlers to interact with the data on the remote endpoint since those handlers do not enforce appropriate permissions. Rockwell Automation recommends enabling built in…

  • CVE-2020-14481HigFeb 24, 2022
    risk 0.51cvss 7.8epss 0.00

    The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an…

  • CVE-2024-37368HigJun 14, 2024
    risk 0.49cvss 7.5epss 0.01

    A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. Due to the lack of proper authentication, this…

  • CVE-2024-37367HigJun 14, 2024
    risk 0.49cvss 7.5epss 0.01

    A user authentication vulnerability exists in the Rockwell Automation FactoryTalk® View SE v12. The vulnerability allows a user from a remote system with FTView to send a packet to the customer’s server to view an HMI project. This action is allowed without proper…

  • CVE-2020-12031HigJul 20, 2020
    risk 0.49cvss 7.5epss 0.01

    In all versions of FactoryTalk View SE, after bypassing memory corruption mechanisms found in the operating system, a local, authenticated attacker may corrupt the associated memory space allowing for arbitrary code execution. Rockwell Automation recommends applying patch…

  • CVE-2020-12027MedJul 20, 2020
    risk 0.35cvss 4.3epss 0.53

    All versions of FactoryTalk View SE disclose the hostnames and file paths for certain files within the system. A remote, authenticated attacker may be able to leverage this information for reconnaissance efforts. Rockwell Automation recommends enabling built in security features…