| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2020-5609 | Cri | 0.64 | 9.8 | 0.02 | Aug 5, 2020 | Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote… | ||
| CVE-2020-5608 | Cri | 0.64 | 9.8 | 0.02 | Aug 5, 2020 | CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to bypass… | ||
| CVE-2022-30707 | Hig | 0.57 | 8.8 | 0.01 | Jun 28, 2022 | Violation of secure design principles exists in the communication of CAMS for HIS. Affected products and versions are CENTUM series where LHS4800 is installed (CENTUM CS 3000 and CENTUM CS 3000 Small R3.08.10 to R3.09.00), CENTUM series where CAMS function is used (CENTUM VP,… | ||
| CVE-2022-22729 | Hig | 0.57 | 8.8 | 0.01 | Mar 11, 2022 | CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00,… |
- risk 0.64cvss 9.8epss 0.02
Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote…
- risk 0.64cvss 9.8epss 0.02
CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to bypass…
- risk 0.57cvss 8.8epss 0.01
Violation of secure design principles exists in the communication of CAMS for HIS. Affected products and versions are CENTUM series where LHS4800 is installed (CENTUM CS 3000 and CENTUM CS 3000 Small R3.08.10 to R3.09.00), CENTUM series where CAMS function is used (CENTUM VP,…
- risk 0.57cvss 8.8epss 0.01
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00,…