VYPR

apk package

wolfi/knative-serving-1.16

pkg:apk/wolfi/knative-serving-1.16

Vulnerabilities (8)

  • CVE-2025-47910MedSep 22, 2025
    affected < 1.16.3-r10fixed 1.16.3-r10

    When using http.CrossOriginProtection, the AddInsecureBypassPattern method can unexpectedly bypass more requests than intended. CrossOriginProtection then skips validation, but forwards the original request path, which may be served by a different handler without the intended sec

  • CVE-2025-47907Aug 7, 2025
    affected < 1.16.3-r8fixed 1.16.3-r8

    Cancelling a query (e.g. by cancelling the context passed to one of the query methods) during a call to the Scan method of the returned Rows can result in unexpected results if other queries are being made in parallel. This can result in a race condition that may overwrite the ex

  • CVE-2025-54410Jul 30, 2025
    affected < 1.16.3-r9fixed 1.16.3-r9

    Moby is an open source container framework developed by Docker Inc. that is distributed as Docker Engine, Mirantis Container Runtime, and various other downstream projects/products. A firewalld vulnerability affects Moby releases before 28.0.0. When firewalld reloads, Docker fail

  • CVE-2025-4673MedJun 11, 2025
    affected < 1.16.3-r5fixed 1.16.3-r5

    Proxy-Authorization and Proxy-Authenticate headers persisted on cross-origin redirects potentially leaking sensitive information.

  • CVE-2025-22874HigJun 11, 2025
    affected < 1.16.3-r5fixed 1.16.3-r5

    Calling Verify with a VerifyOptions.KeyUsages that contains ExtKeyUsageAny unintentionally disabledpolicy validation. This only affected certificate chains which contain policy graphs, which are rather uncommon.

  • CVE-2025-22870MedMar 12, 2025
    affected < 1.16.3-r1fixed 1.16.3-r1

    Matching of hosts against proxy patterns can improperly treat an IPv6 zone ID as a hostname component. For example, when the NO_PROXY environment variable is set to "*.example.com", a request to "[::1%25.example.com]:80` will incorrectly match and not be proxied.

  • CVE-2025-22868Feb 26, 2025
    affected < 1.16.3-r1fixed 1.16.3-r1

    An attacker can pass a malicious malformed token which causes unexpected memory to be consumed during parsing.

  • CVE-2025-22866MedFeb 6, 2025
    affected < 1.16.2-r1fixed 1.16.2-r1

    Due to the usage of a variable time instruction in the assembly implementation of an internal function, a small number of bits of secret scalars are leaked on the ppc64le architecture. Due to the way this function is used, we do not believe this leakage is enough to allow recover