CWE-343
Predictable Value Range from Previous Values
Description
The product's random number generator produces a series of values which, when observed, can be used to infer a relatively small range of possibilities for the next value that could be generated.
Hierarchy (View 1000)
Parents
Children
none
CVEs mapped to this weakness (5)
| CVE | Vendor / Product | Sev | Risk | CVSS | EPSS | KEV | Published | Description |
|---|---|---|---|---|---|---|---|---|
| CVE-2017-7901 | Hig | 0.56 | 8.6 | 0.07 | Jun 30, 2017 | A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;… | ||
| CVE-2017-6030 | Med | 0.42 | 6.5 | 0.02 | Jun 30, 2017 | A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version… | ||
| CVE-2026-33221 | Med | 0.27 | 5.3 | 0.00 | Mar 20, 2026 | Nhost is an open source Firebase alternative with GraphQL. Prior to version 0.12.0, the storage service's file upload handler trusts the client-provided Content-Type header without performing server-side MIME type detection. This allows an attacker to upload files with an… | ||
| CVE-2026-32694 | 0.00 | — | 0.00 | Mar 18, 2026 | In Juju from version 3.0.0 through 3.6.18, when a secret owner grants permissions to a secret to a grantee, the secret owner relies exclusively on a predictable XID of the secret to verify ownership. This allows a malicious grantee which can request secrets to predict past… | |||
| CVE-2014-5409 | 0.00 | — | 0.03 | Mar 14, 2015 | The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values. |
- risk 0.56cvss 8.6epss 0.07
A Predictable Value Range from Previous Values issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions;…
- risk 0.42cvss 6.5epss 0.02
A predictable value range from previous values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version…
- risk 0.27cvss 5.3epss 0.00
Nhost is an open source Firebase alternative with GraphQL. Prior to version 0.12.0, the storage service's file upload handler trusts the client-provided Content-Type header without performing server-side MIME type detection. This allows an attacker to upload files with an…
- CVE-2026-32694Mar 18, 2026risk 0.00cvss —epss 0.00
In Juju from version 3.0.0 through 3.6.18, when a secret owner grants permissions to a secret to a grantee, the secret owner relies exclusively on a predictable XID of the secret to verify ownership. This allows a malicious grantee which can request secrets to predict past…
- CVE-2014-5409Mar 14, 2015risk 0.00cvss —epss 0.03
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.