CVE-2026-80754
Description
In the Linux kernel, the following vulnerability has been resolved:
Input: synaptics-rmi4 - fix F55 transmitter electrode count typo
During F55 sensor detection, the transmitter (TX) electrode count was incorrectly assigned the value of the receiver (RX) electrode count due to copy-paste typos.
This incorrect value was then propagated to the driver data and used by F54 to determine the diagnostics report size. On devices with more RX than TX electrodes, this inflated the perceived TX count, leading to incorrect report size calculations and potential out-of-bounds buffer accesses.
Fix the typos by correctly assigning the TX electrode counts.
AI Insight
LLM-synthesized narrative grounded in this CVE's description and references.
Affected products
1Patches
Vulnerability mechanics
References
8- git.kernel.org/stable/c/0739c65e799d4a93fe573ed23255a71fcfcc5438nvd
- git.kernel.org/stable/c/6058f0fea10f3caf63a435677358d1b8e9325114nvd
- git.kernel.org/stable/c/6484e00d6778fdf2209cd75940bc3902b276457fnvd
- git.kernel.org/stable/c/9759502f5cd71805923457f183ae5b9533e20c7bnvd
- git.kernel.org/stable/c/9b184c8337c6e12df129399007735a7fbcbbcb7bnvd
- git.kernel.org/stable/c/a6d9646e77da7cab2dff7043a8e9f75e23b836bcnvd
- git.kernel.org/stable/c/a81cafe3c3c2f8494063385a7b0ea7ff407bf19fnvd
- git.kernel.org/stable/c/db4e20265ebda729610ca5cf45ca9437462c3f36nvd
News mentions
0No linked articles in our index yet.