Medium severity4.8NVD Advisory· Published Dec 12, 2022· Updated May 7, 2026
CVE-2022-32537
CVE-2022-32537
Description
A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is being paired with other system components. Exploitation requires nearby wireless signal proximity with the patient and the device; advanced technical knowledge is required for exploitation. Please refer to the Medtronic Product Security Bulletin for guidance
Affected products
29- Medtronic/Minimed 600 Series Insulin Pumpv5Range: 620G, 630G, 640G, 670G
- cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7730_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7731_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7738_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:guardian_link_2_transmitter_mmt-7775_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7810_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:guardian_link_3_transmitter_mmt-7811_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_620g_mmt-1750_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_630g_mmt-1715_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_630g_mmt-1754_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_630g_mmt-1755_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_640g_mmt-1711_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_640g_mmt-1712_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_640g_mmt-1751_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_640g_mmt-1752_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1740_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1741_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1742_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1760_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1761_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1762_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1780_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1781_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:minimed_670g_mmt-1782_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:mmt-1151_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:mmt-1152_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:mmt-1351_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:mmt-1352_firmware:-:*:*:*:*:*:*:*
- cpe:2.3:o:medtronic:mmt-7306_firmware:-:*:*:*:*:*:*:*
Patches
0No patches discovered yet.
Vulnerability mechanics
AI mechanics synthesis has not run for this CVE yet.
References
4- global.medtronic.com/xg-en/product-security/security-bulletins/minimed-600-series-communication-issue.htmlnvdMitigationVendor Advisory
- www.cisa.gov/uscert/ics/advisories/icsma-22-263-01nvdThird Party AdvisoryUS Government Resource
- www.cisa.gov/news-events/ics-medical-advisories/icsma-22-263-01nvd
- www.medtronic.com/en-us/e/product-security/security-bulletins/minimed-600-series-communication-issue.htmlnvd
News mentions
0No linked articles in our index yet.