CVE-2022-26648
Description
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204-2 (All versions < V5.2.6), SCALANCE X204-2FM (All versions < V5.2.6), SCALANCE X204-2LD (All versions < V5.2.6), SCALANCE X204-2LD TS (All versions < V5.2.6), SCALANCE X204-2TS (All versions < V5.2.6), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE X206-1 (All versions < V5.2.6), SCALANCE X206-1LD (All versions < V5.2.6), SCALANCE X208 (All versions < V5.2.6), SCALANCE X208PRO (All versions < V5.2.6), SCALANCE X212-2 (All versions < V5.2.6), SCALANCE X212-2LD (All versions < V5.2.6), SCALANCE X216 (All versions < V5.2.6), SCALANCE X224 (All versions < V5.2.6), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204 (All versions < V5.2.6), SCALANCE XF204-2 (All versions < V5.2.6), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SCALANCE XF206-1 (All versions < V5.2.6), SCALANCE XF208 (All versions < V5.2.6). Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
Affected products
61- Siemens/SCALANCE X212-2LDv5Range: All versions < V5.2.6
<V5.5.2+ 2 more
- (no CPE)range: <V5.5.2
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.2.6
<V5.2.6+ 2 more
- (no CPE)range: <V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- Range: <V5.2.6
All versions < V5.5.2+ 2 more
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.5.2
- Range: All versions < V5.5.2
All versions < V5.5.2+ 2 more
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.5.2
All versions < V5.2.6+ 8 more
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- Range: All versions < V5.2.6
All versions < V5.2.6+ 4 more
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.5.2
- (no CPE)range: All versions < V5.2.6
- (no CPE)range: All versions < V5.2.6
All versions < V5.5.2+ 1 more
- (no CPE)range: All versions < V5.5.2
- cpe:2.3:o:siemens:scalance_xf204-2ba_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x204-2_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x204-2fm_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x204-2ld_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x204-2ld_ts_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x204-2ts_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x208_pro_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x202-2p_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x200-4p_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x206-1_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*+ 1 more
- cpe:2.3:o:siemens:scalance_x206-1ld_firmware:*:*:*:*:*:*:*:*range: <5.2.6
- (no CPE)range: All versions < V5.2.6
- cpe:2.3:o:siemens:scalance_x208_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x212-2_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x212-2ld_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x216_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x224_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_xf204_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_xf204-2_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_xf206-1_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_xf208_firmware:*:*:*:*:*:*:*:*Range: <5.2.6
- cpe:2.3:o:siemens:scalance_x201-3p_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x201-3p_irt_pro_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x202-2irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x202-2p_irt_pro_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x204irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_x204irt_pro_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_xf201-3p_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_xf202-2p_irt_firmware:*:*:*:*:*:*:*:*
- cpe:2.3:o:siemens:scalance_xf204irt_firmware:*:*:*:*:*:*:*:*
Patches
Vulnerability mechanics
References
1- cert-portal.siemens.com/productcert/pdf/ssa-310038.pdfnvdPatchVendor Advisory
News mentions
0No linked articles in our index yet.