Unrated severityNVD Advisory· Published Jul 13, 2021· Updated Aug 3, 2024
CVE-2021-31894
CVE-2021-31894
Description
A vulnerability has been identified in SIMATIC PCS 7 V8.2 and earlier (All versions), SIMATIC PCS 7 V9.X (All versions < V9.1 SP2), SIMATIC PDM (All versions < V9.2 SP2), SIMATIC STEP 7 V5.X (All versions < V5.7), SINAMICS STARTER (containing STEP 7 OEM version) (All versions < V5.4 SP2 HF1). A directory containing metafiles relevant to devices' configurations has write permissions. An attacker could leverage this vulnerability by changing the content of certain metafiles and subsequently manipulate parameters or behavior of devices that would be later configured by the affected software.
Affected products
8- Range: < V9.2 SP2
< V5.7+ 1 more
- (no CPE)range: < V5.7
- (no CPE)range: All versions < V5.7
V8.2 and earlier, V9.X < V9.1 SP2+ 2 more
- (no CPE)range: V8.2 and earlier, V9.X < V9.1 SP2
- (no CPE)range: All versions < V9.1 SP2
- (no CPE)range: All versions < V9.2 SP2
- Siemens/SIMATIC PCS 7 V8.2 and earlierv5Range: All versions
- Siemens/SINAMICS STARTER (containing STEP 7 OEM version)v5Range: All versions < V5.4 SP2 HF1