Medtronic Conexus Radio Frequency Telemetry Protocol Improper Access Control
Description
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
AI Insight
LLM-synthesized narrative grounded in this CVE's description and references.
Affected products
26(expand)+ 1 more
- (no CPE)
- (no CPE)range: All versions
24950, 24952+ 1 more
- (no CPE)range: 24950, 24952
- (no CPE)range: 24950
- Medtronic/Amplia CRT-Dv5Range: All versions
- Medtronic/Brava CRT-Dv5Range: All versions
- Range: 2490C
- Medtronic/Claria CRT-Dv5Range: All versions
- Medtronic/Compia CRT-Dv5Range: All versions
- Medtronic/Concerto CRT-Dv5Range: All versions
- Medtronic/Concerto II CRT-Dv5Range: All versions
- Medtronic/Conexus Radio Frequency Telemetry Protocolv5Range: All versions
- Medtronic/Consulta CRT-Dv5Range: All versions
- Medtronic/Evera ICDv5Range: All versions
- Medtronic/Maximo II CRT-Dv5Range: All versions
- Medtronic/Maximo II ICDv5Range: All versions
- Medtronic/Mirro ICDv5Range: All versions
- Medtronic/Mirro MRI ICDv5Range: All versions
- Medtronic/Nayamed ND ICDv5Range: All versions
- Medtronic/Primo ICDv5Range: All versions
- Medtronic/Protecta ICD, Protecta CRT-Dv5Range: All versions
- Medtronic/Secura ICDv5Range: All versions
- Medtronic/Virtuoso ICDv5Range: All versions
- Medtronic/Virtuoso II ICDv5Range: All versions
- Medtronic/Visia AF ICDv5Range: All versions
- Medtronic/Viva CRT-Dv5Range: All versions
Patches
Vulnerability mechanics
References
2- www.securityfocus.com/bid/107544mitrevdb-entryx_refsource_BID
- ics-cert.us-cert.gov/advisories/ICSMA-19-080-01mitrex_refsource_MISC
News mentions
0No linked articles in our index yet.