Medium severity5.5NVD Advisory· Published Dec 13, 2018· Updated Jun 17, 2026
CVE-2018-13811
CVE-2018-13811
Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All Versions < V15.1). Password hashes with insufficient computational effort could allow an attacker to access to a project file and reconstruct passwords. The vulnerability could be exploited by an attacker with local access to the project file. No user interaction is required to exploit the vulnerability. The vulnerability could allow the attacker to obtain certain passwords from the project. At the time of advisory publication no public exploitation of this vulnerability was known.
Affected products
3cpe:2.3:a:siemens:simatic_step_7_\(tia_portal\):*:*:*:*:*:*:*:*+ 1 more
- cpe:2.3:a:siemens:simatic_step_7_\(tia_portal\):*:*:*:*:*:*:*:*range: <15.1
- (no CPE)range: <V15.1
- Siemens AG/SIMATIC STEP 7 (TIA Portal)v5Range: SIMATIC STEP 7 (TIA Portal) : All Versions < V15.1
Patches
Vulnerability mechanics
References
2- www.securityfocus.com/bid/105926nvdThird Party AdvisoryVDB Entry
- cert-portal.siemens.com/productcert/pdf/ssa-621493.pdfnvdVendor Advisory
News mentions
0No linked articles in our index yet.