CVE-2018-11454
Description
A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.
Affected products
3- Range: V10, V11, V12 (all versions), V13 < V13 SP2 Update 2, V14 < V14 SP1 Update 6, V15 < V15 Update 2
- Range: V10, V11, V12 (all versions), V13 < V13 SP2 Update 2, V14 < V14 SP1 Update 6, V15 < V15 Update 2
- Siemens AG/SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15v5Range: SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versions
Patches
Vulnerability mechanics
References
2- www.securityfocus.com/bid/105115nvdThird Party AdvisoryVDB Entry
- cert-portal.siemens.com/productcert/pdf/ssa-979106.pdfnvdVendor Advisory
News mentions