VYPR
Unrated severityNVD Advisory· Published Mar 16, 2014· Updated May 6, 2026

CVE-2014-2246

CVE-2014-2246

Description

Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.

AI Insight

LLM-synthesized narrative grounded in this CVE's description and references.

The integrated web server in Siemens SIMATIC S7-1500 CPU PLCs before V1.5 is vulnerable to stored/reflected cross-site scripting (XSS) via unspecified vectors.

Vulnerability

A cross-site scripting (XSS) vulnerability exists in the integrated web server of Siemens SIMATIC S7-1500 CPU programmable logic controllers (PLCs) with firmware versions prior to V1.5[1]. The flaw allows an attacker to inject arbitrary web script or HTML through unspecified vectors, indicating that user-controllable input is not properly sanitized before being rendered in a web page served by the device[1][2].

Exploitation

An unauthenticated attacker can exploit this vulnerability remotely over the network by sending a specially crafted HTTP(S) request to port 80/TCP or port 443/TCP of the affected PLC[1]. The attacker does not require any prior authentication or special privileges. Successful exploitation may require some social engineering to convince a legitimate user to visit a crafted link or interact with malicious content, but the technical vector is straightforward[1].

Impact

A successful XSS attack enables the attacker to execute arbitrary JavaScript in the context of the victim's browser session when they view the attacked page. This could lead to session hijacking, defacement of the PLC's web interface, theft of credentials, or further malicious actions performed as the authenticated user. The vulnerability compromises the confidentiality and integrity of the user's interaction with the device, potentially enabling unauthorized control actions[1].

Mitigation

Siemens released firmware version V1.5 to address this vulnerability[1]. All users of SIMATIC S7-1500 CPU family devices should update to V1.5 or later. If upgrading is not immediately possible, Siemens recommends restricting network access to the device's web server to trusted users and networks, as well as following general industrial control system security best practices[1]. No workaround other than applying the firmware patch has been provided.

AI Insight generated on May 23, 2026. Synthesized from this CVE's description and the cited reference URLs; citations are validated against the source bundle.

Affected products

5
  • cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*+ 3 more
    • cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:*:*:*:*:*:*:*:*range: <=1.1.2
    • cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:1.0.1:*:*:*:*:*:*:*
    • cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:1.1.0:*:*:*:*:*:*:*
    • cpe:2.3:o:siemens:simatic_s7-1500_cpu_firmware:1.1.1:*:*:*:*:*:*:*
  • Range: <1.5.0

Patches

0

No patches discovered yet.

Vulnerability mechanics

AI mechanics synthesis has not run for this CVE yet.

References

4

News mentions

0

No linked articles in our index yet.