CVEs (14)

  • CVE-2016-5743CriJul 22, 2016
    risk 0.65cvss 9.8epss 0.18

    Siemens SIMATIC WinCC before 7.3 Update 10 and 7.4 before Update 1, SIMATIC BATCH before 8.1 SP1 Update 9 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.1 Update 3 as distributed in SIMATIC PCS 7 through 8.1 SP1, SIMATIC OpenPCS 7 before 8.2 Update 1…

  • CVE-2016-9160HigDec 17, 2016
    risk 0.53cvss 8.1epss 0.00

    A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking…

  • CVE-2010-2772HigJul 22, 2010
    risk 0.51cvss 7.8epss 0.00

    Siemens Simatic WinCC and PCS 7 SCADA system uses a hard-coded password, which allows local users to access a back-end database and gain privileges, as demonstrated in the wild in July 2010 by the Stuxnet worm, a different vulnerability than CVE-2010-2568.

  • CVE-2016-5744HigJul 22, 2016
    risk 0.49cvss 7.5epss 0.01

    Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets.

  • CVE-2015-2823Apr 8, 2015
    risk 0.00cvss epss 0.01

    Siemens SIMATIC HMI Basic Panels 2nd Generation before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC HMI Comfort Panels before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Advanced before WinCC (TIA Portal) 13 SP1 Upd2, SIMATIC WinCC Runtime Professional before WinCC (TIA…

  • CVE-2014-4686Jul 24, 2014
    risk 0.00cvss epss 0.00

    The Project administration application in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, has a hardcoded encryption key, which allows remote attackers to obtain sensitive information by extracting this key from another product installation and then…

  • CVE-2014-4685Jul 24, 2014
    risk 0.00cvss epss 0.00

    Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows local users to gain privileges by leveraging weak system-object access control.

  • CVE-2014-4684Jul 24, 2014
    risk 0.00cvss epss 0.00

    The database server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a request to TCP port 1433.

  • CVE-2014-4683Jul 24, 2014
    risk 0.00cvss epss 0.00

    The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote authenticated users to gain privileges via a (1) HTTP or (2) HTTPS request.

  • CVE-2014-4682Jul 24, 2014
    risk 0.00cvss epss 0.00

    The WebNavigator server in Siemens SIMATIC WinCC before 7.3, as used in PCS7 and other products, allows remote attackers to obtain sensitive information via an HTTP request.

  • CVE-2014-1699Feb 7, 2014
    risk 0.00cvss epss 0.01

    Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999.

  • CVE-2014-1698Feb 7, 2014
    risk 0.00cvss epss 0.01

    Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999.

  • CVE-2014-1697Feb 7, 2014
    risk 0.00cvss epss 0.05

    The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999.

  • CVE-2014-1696Feb 7, 2014
    risk 0.00cvss epss 0.01

    Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack.